The technical scales are designed for more measurement precision. They
have 15000, 20000 or 30000 divisions.
The mechanical construction of the technical scales are based on these
of the platform and retail scales.

Technical scales with 15000 divisions:
| SCALE |
PLATFORM |
| TYPE |
Maximum Capacity
(in kg) |
Division
(in g) |
K0150 |
K3Ò |
K10T |
K30 |
K60 |
K150 |
K300 |
K600 |
|
Â0150 |
0,150 |
0,01 |
* |
|
|
|
|
|
|
|
|
Â0300 |
0,300 |
0,02 |
* |
|
|
|
|
|
|
|
|
B0750 |
0,750 |
0,05 |
* |
|
|
|
|
|
|
|
|
B1,5T |
1,5 |
0,1 |
|
* |
|
|
|
|
|
|
|
Â3T |
3 |
0,2 |
|
* |
*
|
|
|
|
|
|
|
B7,5T |
7,5 |
0,5 |
|
* |
*
|
* |
|
|
|
|
|
Â15T |
15 |
1 |
|
|
*
|
* |
|
|
|
|
|
Â30T |
30 |
2 |
|
|
|
* |
|
|
|
|
|
Â75T |
75 |
5 |
|
|
|
|
* |
* |
|
|
|
Â150T |
150 |
10 |
|
|
|
|
|
* |
|
|
|
Â300T |
300 |
20 |
|
|
|
|
|
* |
* |
* |
|
Â750T |
750 |
50 |
|
|
|
|
|
|
|
* |
Technical scales with 20000/30000 divisions:
| SCALE |
PLATFORM |
| TYPE |
Maximum Capacity
(in kg) |
Division (in g) |
K0150 |
K3Ò |
K10T |
K30 |
K60 |
K150 |
K300 |
|
Â0300P |
0,300 |
0,01 |
* |
|
|
|
|
|
|
|
Â0600P |
0,600 |
0,02 |
* |
|
|
|
|
|
|
|
B3P |
3 |
0,1 |
|
* |
|
|
|
|
|
|
B6P |
6 |
0,2 |
|
|
*
|
|
|
|
|
|
Â10P |
10 |
0,5 |
|
|
*
|
|
|
|
|
|
B30P |
30 |
1 |
|
|
|
* |
|
|
|
|
Â60P |
60 |
2 |
|
|
|
|
*
|
|
|
|
Â100P |
100 |
5 |
|
|
|
|
|
*
|
|
|
Â300P |
300 |
10 |
|
|
|
|
|
* |
*
|
Counting scales:
| SCALE |
PLATFORM |
| TYPE |
Maximum Capacity
(in kg) |
Division in weighing mode
(in g) |
Readability in counting mode (in g) |
K0150 |
K3T |
K10T |
K30 |
K60 |
K150 |
K300 |
K600 |
|
Â0600F |
0,600 |
0,2 |
0,04 |
* |
*
|
|
|
|
|
|
|
|
B1,5F |
1,5 |
0,5 |
0,1 |
|
*
|
|
|
|
|
|
|
|
B3F |
3 |
1 |
0,2 |
|
*
|
*
|
*
|
|
|
|
|
|
B6F |
6 |
2 |
0,4 |
|
*
|
*
|
*
|
|
|
|
|
|
Â15F |
15 |
5 |
1 |
|
|
*
|
*
|
|
|
|
|
|
Â30F |
30 |
10 |
2 |
|
|
|
*
|
|
|
|
|
|
Â60F |
60 |
20 |
4 |
|
|
|
|
*
|
* |
|
|
|
Â150F |
150 |
50 |
10 |
|
|
|
|
|
* |
|
|
|
Â300F |
300 |
100 |
20 |
|
|
|
|
|
* |
*
|
*
|
|
Â600F |
600 |
200 |
40 |
|
|
|
|
|
|
|
*
|
Filling (Dosing) Scales
To all types of scales can be added dosing
functions.
The scale is supplied with two relay exits. At first user can give one or two weight levels to the scale.
When the weight reaches the weight level-the relay switch on and gives the signal.
This is used for breaking the process of filling the scale with the material.
For a higher bigger productivity we recommend the use of two weight levels.
- for rough dosing - with big debit
- for finely dosing - with small debit
The levels of dosing can be negative as well.
That function can be used for dosing when removing material.
At first user gives one or two negative levels to scale. After that he puts the material in same container.
He puts the vessel on the platforms of the scale and pushes the button TARE.
When the material reaches the negative level the scale an electrical signal is given.
This signal can manage different processes of automatic systems.
|